KSR Low Loss Cable
KSR Low Loss Cable
Construction Specification
Item | Material | Diameter(mm) |
---|---|---|
1. Inner Conductor | Solid Copper or Copper Clad Aluminum | 1.78 |
2. Dielectric | Physical Foam Polyethylene | 4.83 |
3. Outer Conductor | Bonded Aluminum Foil + Tinned Copper Braid | Nom.5.72 |
4. Jacket | Polyethylene | 7.62 |
Electrical Characteristics
Capacitance(pF/m) | 79.1 |
Impedance(ohm) | 50 |
Velocity of Propagation(%) | 85 |
Inner Conductor DC Resistance(ohm/m) | 7.28/11.56 |
Outer Conductor DC Resistance(ohm/m) | 7.62 |
Jacket Voltage Withstanding(Vrms) | 5000 |
Peak Power(KW) | 10 |
Shielding Effectiveness(>dB) | 90 |
Mechanical and Environmental Characteristics
Operating Temp(℃) | -40 to +80 |
Bending Radius(mm) | 38 |
ROHS | Compliant |
Attenuation and Avg. Power(20℃)
Frequency(MHz) | Attenuation(dB/100m) | Avg. Power(KW) |
---|---|---|
30 | 3.5 | 1.78 |
50 | 4.5 | 1.38 |
150 | 7.9 | 0.79 |
220 | 9.6 | 0.65 |
450 | 13.8 | 0.45 |
900 | 19.9 | 0.31 |
1500 | 26.0 | 0.24 |
1800 | 28.7 | 0.22 |
2000 | 30.3 | 0.21 |
2500 |
34.2 |
0.18 |
5800 | 54.3 | 0.11 |