Stock Code:300252.SZ
English

Construction Characteristic

  Item  Material  Diameter(mm)
  1. Inner Conductor    Copper Clad Aluminum or Copper   2.6
  2. Dielectric    Physical Foam Polyethylene   6.7
  3. Outer Conductor

   Helical Copper Tube

  9.1
  4. Jacket    PE or Low Smoke Halogen Free Fire Retardant PE   10.2

Electrical Characteristic

  Capacitance(pF/m)   80
  Impedance(ohm)   50
  Velocity of Propagation(%)   83
  Peak Power(KW)   12
  RF Peak Voltage(KV)   1.04
  Insulation Resistance(MΩ.km)   >5000
  Cutoff Frequency(GHz)   13.4
  Insulation Voltage(KVrms)   2.5
  Inner Conductor DC Resistance(Ω/km)   5.4/3.4
  Outer Conductor DC Resistance(Ω/km)   3.5
  Jacket Spark(KVrms)   3.0
  Shielding Effectiveness(dB)   >120

Mechanical and Environmental Characteristic

  Min Single Bending Radius(mm)   12.5
  Min Repeated Bending Radius(mm)   25
  No.of Bends   15
  Tensile Strength(kg)   60
  Storage Temp.(℃)   -55 to +85
  Installation Temp.(℃)   -20 to +60
  Operating Temp.(℃)   -55 to +85

Attenuation(VSWR1.0,Cable temp.20℃)and Average Power(VSWR1.0,ambient temp.40℃)

  Frequency(MHz)  Attenuation(dB/100m)  Average Power(KW)
  100   4.18   1.90
  200   5.96   1.30
  450   9.14   0.87
  800   12.32   0.64
  900   13.15   0.60
  1000   13.85   0.57
  1500   17.35   0.45
  1800   19.20   0.41
  2000   20.30   0.39
  2200   21.40   0.37
  2400   22.50   0.36
  2500   23.00   0.35
  3000   25.20   0.31
SHARE:
`