1, home improvement optical cable line should pay attention to the floor of the building do not all pavement marble. Marble is more than a few times heavier than the weight of floor tiles and wood floors, and if the floor is full of marble, it is possible to overwhelm the floor. Especially on the second floor, because the housing safety identification station without the identification of housing decoration, the ground decoration material weight shall not exceed 40 kg / square meter.

 

2, the room decoration, not free to wear holes in the load-bearing walls, the demolition of the balcony and doors and windows connected to the wall and the expansion of the original doors and windows or the size of the doors and windows, this approach will cause local cracks and serious impact on seismic capacity, thus shortening Building life.

 

3, balcony, bathroom decoration should try to use the load of small materials, because the balcony over-over will be overturned.

 

4, toilet bath waterproofing is also a key link in the decoration. The general practice is to install the toilet before the bathroom, the first to block the floor drain, put more than 5 cm of water, the water test, if the water leakage, must be redo waterproof; if not leak, but also in the construction of careful laying the ground , Do not damage the waterproof layer and unauthorized changes to the water and heating system.

 

5, in the room decoration in order to pursue luxury, in the walls covered with plate, ceiling trim two three-dimensional three-dimensional ceiling, this decoration is not desirable. Because the walls covered with sheet metal, occupy a larger space, will reduce the size of the entire space, the cost is also a higher cost, while not conducive to fire. The ceiling is too low to make the whole room feel depressed.

 

6, select the wire to use copper, avoid using aluminum. As the aluminum wire conductivity is poor, easy to use in the heating wire, joints loose or even lead to fire. Also in the construction should also be noted that can not be directly on the wall trench buried wire, should be used to install the regular casing to avoid leakage and cause a fire.

 

7, in the construction should pay attention to avoid the hole in the concrete hole hole, drilling, hanging ceiling and the installation of art lighting.

 

8, interior decoration to ensure that the gas pipeline and equipment safety requirements, do not unauthorized removal of the pipeline, so as not to affect the normal operation of the system. Also pay attention to the power pipeline and equipment and gas pipeline horizontal net distance of not less than 10 cm, wire and gas pipe cross distance of not less than 3 cm.

 

9, the kitchen decoration do not put the gas stove in the wooden cabinet, but can not be the total gas valve package in the wooden cabinet. Once the cabinet fire, gas valve in the fire is difficult to close, the consequences will be disastrous.